MITSUBISHI FX1S-30MT-D Manual FX1S-30MT-D HARDWARE MANUAL
Product model: FX1S-30MT-D
Name: PLC
Brand: MITSUBISHI
Sort: HARDWARE MANUAL
File language: English
Analog input points: 4 points (PT1000/Nil000).
Resolution: 0.1 degrees.
Weight: 0.1kg.
Dimensions: 17.6 x 90 x 89.5.
FX3U-4AD-PNK-ADP is a PT1000/Nil000 temperature sensor with analog input adapter.
Thermocouple (K type, J type) and PT1000/Nil000 temperature sensor with analog input adapter.
-100~1000 degree can be measured by 4 channels FX1S-30MT-D Manual FX1S-30MT-D HARDWARE MANUAL.
No programming to send data to FX3 series FX1S-30MT-D
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U,
Need to convert adapter or function extension board. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 75kw.
SLD converter rated current: 380A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel FX1S-30MT-D Manual FX1S-30MT-D HARDWARE MANUAL. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units FX1S-30MT-D Manual FX1S-30MT-D HARDWARE MANUAL.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. Power: 7.5kw.
Voltage: 200V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 15KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, thhe impact on the mechanical and electrical FX1S-30MT-D Manual FX1S-30MT-D HARDWARE MANUAL.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FX1S-30MT-D Manual FX1S-30MT-D HARDWARE MANUAL.
Related products
MITSUBISHI
PLC
FX1S-30MR-D
MITSUBISHI PLC FX1S-30MR-D
Max input / output points: 30 points. Po
MITSUBISHI
PLC
FX1S-14MR-D
MITSUBISHI PLC FX1S-14MR-D
Max input / output points: 14 points. Po
MITSUBISHI
PLC
FX1S-20MT-D
MITSUBISHI PLC FX1S-20MT-D
Max input / output points: 20 points. Po
MITSUBISHI
PLC
FX1N-60MT-D
MITSUBISHI PLC FX1N-60MT-D
Max input / output points: 60 points. Po