MITSUBISHI FX1S-14MR-DS Manual FX1S-14MR-DS HARDWARE MANUAL
Product model: FX1S-14MR-DS
Name: PLC
Brand: MITSUBISHI
Sort: HARDWARE MANUAL
File language: English
"Max input / output points: 10 points.
Supply voltage: 100 - 240VAC.
Input points: 6 points.
Output points: 4 points.
Output type: Transistor (source).
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75.
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14 FX1S-14MR-DS Manual FX1S-14MR-DS HARDWARE MANUAL FX1S-14MR-DS
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment FX1S-14MR-DS Manual FX1S-14MR-DS HARDWARE MANUAL. "MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 45KW.
Inverter general area of domestic enterprises to occupy more than 80% of the market share,
Production of frequency converter, motor soft starter and other industrial automation control of the manufacturers, the use of heavy-duty design products,
Overload capacity, with super large start and running capacity, improve the automatic detection, protection and control performance,
Can start and control any type of heavy duty motor,
Products have been widely used in metallurgy, mining, paper, chemicals, building materials, machinery, electricity, and construction systems and other industrial transmission areas FX1S-14MR-DS Manual FX1S-14MR-DS HARDWARE MANUAL. "MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 18.5KW.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called recctification FX1S-14MR-DS Manual FX1S-14MR-DS HARDWARE MANUAL.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixeed frequency and a certain voltage of the inverter FX1S-14MR-DS Manual FX1S-14MR-DS HARDWARE MANUAL.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter. "
Related products
MITSUBISHI
PLC
FX1S-10MT-001
MITSUBISHI PLC FX1S-10MT-001
Total points: 10 points. Input points: 6
MITSUBISHI
PLC
FX1S-14MT-001
MITSUBISHI PLC FX1S-14MT-001
Total points: 14 points. Input points: 8
MITSUBISHI
PLC
FX1S-10MT-ES/UL
MITSUBISHI PLC FX1S-10MT-ES/UL
Max input / output points: 10 points. Su
MITSUBISHI
PLC
FX1S-10MT-D
MITSUBISHI PLC FX1S-10MT-D
Max input / output points: 10 points. Po