Power: 560kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V FX Series UL FX Series Underwriters Laboratories Inc.
Power: 450kw.
SLD converter rated current: 1094A
FX Series
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
To maximize the performance of the motor.
Advanced auto tuning function.
The newly developed PM motor auto tuning feature can be used to operate other manufacturers of PM motors (Yong Ci synchronous motors) in the sensorless state.
Not only can drive MITSUBISHI induction motor and PM motor, but also can drive other manufacturers of induction motor and PM motor FX Series UL FX Series Underwriters Laboratories Inc.
This means that you can reduce the cost of inventory and supplies.
If the PM motor is produced by a IPM motor or other company using MM-CF, the starting torque is limited to 50%,
Even after tuning is not simple to use and positioning control of zero speed torque) induction motor and permanent magnet motor can be combined freely FX Series UL FX Series Underwriters Laboratories Inc. "Power: 30kw.
Voltage: 200V.
Brake resistor, a kind of ripple resistance, is mainly used in the mechanical system of the inverter to control the speed of the motor,
Help the motor to be converted into heat energy due to the regenerative power of the motor.
Braking unit principle: the brake unit is composed of a high power transistor GTR and its driving circuit.
Its function is to link the discharge current braking resistor capacitor voltage or not in the range of the time consumed and the DC part "overpressure",
Need to add external braking components, in order to speed up the speed of the consumption of renewable energy. "Function extension board for RS-485 communication.
No DC24V consumption, do not take up input and output. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 0.4kw.
SLD converter rated current: 4.6A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce thee volume of equipment) FX Series UL FX Series Underwriters Laboratories Inc.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network FX Series UL FX Series Underwriters Laboratories Inc.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.