Output points: 32 points.
Output form: Transistor (source) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.1A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 40 pin connector RV-12SD Series Manual RV-12SD Series Instruction Manual.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type
RV-12SD Series
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point RV-12SD Series Manual RV-12SD Series Instruction Manual.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance. DC input, transistor (drain type) output.
Channel number: 2CH.
External wiring connection mode: 40 pin connector
Count input signal: there
Single phase input (single frequency / double frequency)
Dual phase input (single frequency and double frequency /4)
CW/CCW input: there
The signal level (phi A, Phi B): 2 ~ 5mA DC5/12/24V RV-12SD Series Manual RV-12SD Series Instruction Manual.
High speed counter module can be measured in 200kpulse/s when DC input,
8Mpulse/s measurement can be performed in a differential input.
The use of high precision incremental encoder, the most suitable for location tracking.
In addition, the high-speed counter module is also equipped with a pulse measurement and PWM output and other functions. Analog input channel number: 4CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection mode: 18 point screw terminal.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Channel insulation.
Similar to the input and output modules, analog quantity module is the interface between the sensor and the programmable controller.
The difference between the input annd output modules is that it is dealing with analog voltage and current signals rather than ON/OFF signals RV-12SD Series Manual RV-12SD Series Instruction Manual.
The analog module MELSEC iQ-R series is equipped with high-speed conversion (80 s/CCH), high resolution (1/32000), channel insulation, abnormal signal detection and other convenient features,
Can achieve high precision analog control RV-12SD Series Manual RV-12SD Series Instruction Manual.