Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A68RD4N Manual A68RD4N User's Manual.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool
A68RD4N Input and output points: 256 points.
Input / output data points: 256 points.
Program capacity: 6k.
Basic command processing speed (LD command) s:1.0.
Internal storage RAM memory capacity: 16k A68RD4N Manual A68RD4N User's Manual.
Optical data communication line function with power supply.
Input / output data control mode conversion.
It is possible to enter the control of the output data as the following 3.
(1) input: direct mode, output: direct mode.
(2) input: I/O impression update mode, output: direct mode.
(3) input: I/O impression update mode, output: I/O impression update mode A68RD4N Manual A68RD4N User's Manual.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance. Data communication line module (coaxial cable) Master / local station for A3VTS multiplex system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures A68RD4N Manual A68RD4N User's Manual.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures.
Protection aand chain is an indispensable part of the program, must be carefully considered A68RD4N Manual A68RD4N User's Manual.
It can avoid the control logic confusion caused by illegal operations.