MITSUBISHI A1S62RD3N Manual A1S62RD3N User's Manual
Product model: A1S62RD3N
Name: Pt100 Input Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Enter 16 points.
Voltage and current: 14mA DC24V.
Response time: 8ms.
16 point 1 public end, 20 point terminal.
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book A1S62RD3N Manual A1S62RD3N User's Manual A1S62RD3N
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device related to the MITSUBISHI PLC,
To determine the I/O PLC points A1S62RD3N Manual A1S62RD3N User's Manual. For A6TBXY36/A6TBXY54/A6TBX70E (common cathode; drain type) long 3m.Available network: Profibus-FMS.
Function: client or host.
The A1SJ71PB96F and A1SJ71PB92D modules allow a PLC ANS to connect to the Profibus system,
Meet the CE standard, using SWOIX/ProfiMap special programming software.
A1SJ71PB96F compatible with Profibus-FMS, as a master or client;
A1SJ71PB92D compatible with Profibus-DP, can be used as a master to control the remote Profibus-DP I/O A1S62RD3N Manual A1S62RD3N User's Manual. Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input DC5V output 2A DC24V/.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure of how much the useer application can store the number of indicators A1S62RD3N Manual A1S62RD3N User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words A1S62RD3N Manual A1S62RD3N User's Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Temperature control module
A1S62TCRT-S2
MITSUBISHI Temperature control module A1S62TCRT-S2
Numer of channels: 2 channels. Sensing
MITSUBISHI
Temperature control module
A1S64TCTRT
MITSUBISHI Temperature control module A1S64TCTRT
The most appropriate temperature regulat
MITSUBISHI
Temperature control module
A1S64TCTT-S1
MITSUBISHI Temperature control module A1S64TCTT-S1
Numer of channels: 4 channels. Sensing
MITSUBISHI
Power module
A1S62PN
MITSUBISHI Power module A1S62PN
Input voltage: AC100-240V. Rated output: