LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A3ACPU Manual A3ACPU User's Manual
Product model: A3ACPU
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
3C-2V/5C-2V coaxial cable.
Single bus.
Remote I/O network (remote control station).
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps A3ACPU Manual A3ACPU User's Manual A3ACPU
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram A3ACPU Manual A3ACPU User's Manual.
So far the system''s hardware electrical circuit has been determined. DC input points: 2 points.
Input voltage and current: 7mA, DC24V.
Input response time: 10ms.
2 point /1 a public side.
Positive pole sharing.
Output points: 2 points.
Output voltage and current: DC24V.
Output response time: 2ms.
2 point /1 a public side A3ACPU Manual A3ACPU User's Manual.
Output form: transistor output, leakage type.
16 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debuggingg
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A3ACPU Manual A3ACPU User's Manual A3ACPU Manual A3ACPU User's Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
CPU unit
Q3ACPU
MITSUBISHI CPU unit Q3ACPU
Input and output points: 2048 points. In
MITSUBISHI
General purpose CPU
Q00UJCPU
MITSUBISHI General purpose CPU Q00UJCPU
Input / output points: 256 points. Nume
MITSUBISHI
Moving CPU unit
A173UHCPU
MITSUBISHI Moving CPU unit A173UHCPU
CPU:A3UCPU PLC is the same. PLC program