LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A2NCPUP21 Dedicated Instructions Manual A2NCPUP21 Programming Manual
Product model: A2NCPUP21
Name: PLC
Brand: MITSUBISHI
Sort: Dedicated Instructions Programming Manual
File language: English
Source type output module (standard type).RS-232 2 channel.
Transmission speed: 2 channel total is 115.2kbps.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system A2NCPUP21 Dedicated Instructions Manual A2NCPUP21 Programming Manual.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system A2NCPUP21
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved A2NCPUP21 Dedicated Instructions Manual A2NCPUP21 Programming Manual.
Q series PLC in the use of CC-Link function better,
And easier to use. Input points: 16 points.
Input voltage and current: 120V ~ 6mA AC100.
Input response time: 30ms.
16 point /1 a public side.
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end A2NCPUP21 Dedicated Instructions Manual A2NCPUP21 Programming Manual.
Output response time: 12ms.
Output type: relay.
8 point /1 a public side.
50 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control too 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A2NCPUP21 Dedicated Instructions Manual A2NCPUP21 Programming Manual A2NCPUP21 Dedicated Instructions Manual A2NCPUP21 Programming Manual.
Related products
MITSUBISHI
CPU unit
A2NCPUP21-S1
MITSUBISHI CPU unit A2NCPUP21-S1
Input and output points: 1024 points. In
MITSUBISHI
Moving CPU unit
A73CPUP21
MITSUBISHI Moving CPU unit A73CPUP21
Multi axis positioning controller. Optic
MITSUBISHI
CPU unit
A2NCPUR21-S1
MITSUBISHI CPU unit A2NCPUR21-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A0J2HCPUP21
MITSUBISHI CPU unit A0J2HCPUP21
Input and output points: 480 points. Inp