LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A2ACPUR21 PID Control Instructions Manual A2ACPUR21 Programming Manual
Product model: A2ACPUR21
Name: PLC
Brand: MITSUBISHI
Sort: PID Control Instructions Programming Manual
File language: English
Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: relay output.
Output points: 16 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A A2ACPUR21 PID Control Instructions Manual A2ACPUR21 Programming Manual A2ACPUR21
External connection: 1 line /1 line type.
A2C shape terminal.
Type of input and output terminal.
Shape and A2C input and output modules are identical (same mounting dimensions),
Machining and installing holes are not required. 3C-2V/5C-2V coaxial cable.
Single bus.
Remote I/O network (remote control station).
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc A2ACPUR21 PID Control Instructions Manual A2ACPUR21 Programming Manual. .
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps.
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc A2ACPUR21 PID Control Instructions Manual A2ACPUR21 Programming Manual. .
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram.
So far the system''s hardware electrical circuit has been determined. Storage capacity: 64MB.
Applicable models: A985 (-V) /A975/A970/A960GOT (-B). Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 4 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulatiion debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A2ACPUR21 PID Control Instructions Manual A2ACPUR21 Programming Manual A2ACPUR21 PID Control Instructions Manual A2ACPUR21 Programming Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
CPU unit
A2ACPU-S1
MITSUBISHI CPU unit A2ACPU-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A2ACPU
MITSUBISHI CPU unit A2ACPU
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A2CCPUR21
MITSUBISHI CPU unit A2CCPUR21
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A3NCPUR21
MITSUBISHI CPU unit A3NCPUR21
Input and output points: 2048 points. In