LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A2ACPUP21 PID Control Instructions Manual A2ACPUP21 Programming Manual
Product model: A2ACPUP21
Name: PLC
Brand: MITSUBISHI
Sort: PID Control Instructions Programming Manual
File language: English
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0 A2ACPUP21 PID Control Instructions Manual A2ACPUP21 Programming Manual. 5A.
External connection: 1 line /1 line type A2ACPUP21
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A2ACPUP21 PID Control Instructions Manual A2ACPUP21 Programming Manual. Category: Master station.
Transfer speed: 125kbps/250kbps/500kbps/1Mbps.
Transmission line form: bus system.
Total distance: 125kbps:1000m/250kbps:800m/500kbps:480m/1Mbps:240m.
The maximum connection units: 32.
Total points: input + output <=2048 point.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add A2ACPUP21 PID Control Instructions Manual A2ACPUP21 Programming Manual.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. DC input points: 8 points.
Input voltage and current: 7mA, DC24V.
Response time: 10ms.
8 point /1 a public side.
Positive / negative sharing.
24 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debugging
The basic idea of program simulatiion debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A2ACPUP21 PID Control Instructions Manual A2ACPUP21 Programming Manual A2ACPUP21 PID Control Instructions Manual A2ACPUP21 Programming Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
CPU unit
A2ACPU
MITSUBISHI CPU unit A2ACPU
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A2ACPUP21-S1
MITSUBISHI CPU unit A2ACPUP21-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A2ACPUR21
MITSUBISHI CPU unit A2ACPUR21
Input and output points: 512 points. Inp
MITSUBISHI
CPU unit
A2ACPU-S1
MITSUBISHI CPU unit A2ACPU-S1
Input and output points: 1024 points. In