MITSUBISHI A1SY41 Manual A1SY41 User's Manual
Product model: A1SY41
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Analog channel: 12 channels.
Input / output (resolution): 0 ~ 4000.
Conversion speed: 100ms/12 channel.
Analog module installation.
Power supply: AC85 ~ 132V.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system A1SY41 Manual A1SY41 User's Manual A1SY41
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A1SY41 Manual A1SY41 User's Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness A1SY41 Manual A1SY41 User's Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. A set of 5 (LOGO removable, man-machine interface provides one).
Applicable model: A95_GOT (-M3). Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
Coaxial data communication line function.
AnNCPU command processing time and ACPU compare to 10-20% high speed processing.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Integral typee: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure A1SY41 Manual A1SY41 User's Manual A1SY41 Manual A1SY41 User's Manual.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Related products
MITSUBISHI
Input module
A1SX10EU
MITSUBISHI Input module A1SX10EU
Input type: AC. Input points: 16 points.
MITSUBISHI
High speed interrupt module
A1SI61
MITSUBISHI High speed interrupt module A1SI61
A1SI61 is designed to control the applic
MITSUBISHI
DC source type input module
A1SX80-S2
MITSUBISHI DC source type input module A1SX80-S2
Type of input: DC source. Input points:
MITSUBISHI
Temperature control module
A1S64TCTT-S1
MITSUBISHI Temperature control module A1S64TCTT-S1
Numer of channels: 4 channels. Sensing