LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A1SJ71QE71N-B5 Hardware Manual A1SJ71QE71N-B5 User's Manual
Product model: A1SJ71QE71N-B5
Name: Ethernet Interface Module
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
Data format: RTU.
Data bits: 8.
A1SJ71UC24-R2-S2 and A1SJ71UC24-R4-S2 allow the Ans series PLC to be connected to the MODBUS network,
As the network from the station, and in accordance with the instructions of the main station of the CPU Ans user storage area for data reading / writing.
In addition to supporting the MODBUS protocol, these components also support the standard dedicated communication protocol for A1SJ71UC24 components A1SJ71QE71N-B5 Hardware Manual A1SJ71QE71N-B5 User's Manual A1SJ71QE71N-B5
This feature makes the main station of the data acquisition and control with more flexibility.
Support MODBUS slave station protocol.
Supports 1 to 21 function code.
Two transmission modes: RTU or ASCII. 10BASE5.
When communicating in the PLC network of MITSUBISHI,
There is no sense of difference and discontinuity in the network,
Can carry on the remote monitoring, modification, debugging and other work of data communication and program,
Without taking into account the level and type of network A1SJ71QE71N-B5 Hardware Manual A1SJ71QE71N-B5 User's Manual.
MELSECNET/H and CC-Link use the way of loop communication,
Periodically automatically send and receive messages,
Does not require specialized data communication procedures,
Simple parameters can be set A1SJ71QE71N-B5 Hardware Manual A1SJ71QE71N-B5 User's Manual.
MELSECNET/H and CC-Link are used to transmit and receive the broadcast mode,
This can be done on the network data sharing.
For the use of Ethernet, MELSECNET/H, CC-Link network,
Can set the network parameters and various functions, simple and convenient in the Developer GX software screen. 34 point with the wiring transformation adapter 2 line type 16 point input CC-Link unit installation special connection conversion adapterQCPU (Q mode) bus connection.
1 joint.
Applicable models: A985 (-V) /975/970/960GOT. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0.5A.
External connection: 1 line /1 line type.
Accordding to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A1SJ71QE71N-B5 Hardware Manual A1SJ71QE71N-B5 User's Manual.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A1SJ71QE71N-B5 Hardware Manual A1SJ71QE71N-B5 User's Manual.