MITSUBISHI A1SJ71E71N-B2  Manual A1SJ71E71N-B2  User's Manual
Product model: A1SJ71E71N-B2 
Name: Ethernet Interface Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output A1SJ71E71N-B2  Manual A1SJ71E71N-B2  User's Manual.
8 point /1 a public end, 4 points / a public end A1SJ71E71N-B2 
36 point terminal station.
With short circuit protection.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A1SJ71E71N-B2  Manual A1SJ71E71N-B2  User's Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A1SJ71E71N-B2  Manual A1SJ71E71N-B2  User's Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
Thee output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A1SJ71E71N-B2  Manual A1SJ71E71N-B2  User's Manual. .
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A1SJ71E71N-B2  Manual A1SJ71E71N-B2  User's Manual.
Related products
MITSUBISHI
Ethernet interface module
A1SJ71E71-B2-S3
MITSUBISHI Ethernet interface module A1SJ71E71-B2-S3
Availale network: 10BASE2. Max / total
MITSUBISHI
Ethernet module
A1SJ71E71N-B2
MITSUBISHI Ethernet module A1SJ71E71N-B2
10BASE2. PLC is introduced y the relay
MITSUBISHI
Network module
A1SJ71E71N-T
MITSUBISHI Network module A1SJ71E71N-T
10BASE-T MITSUBISHI PLC is the main prod
MITSUBISHI
Ethernet module
A1SJ71E71N3-T
MITSUBISHI Ethernet module A1SJ71E71N3-T
10BASE-T. The structured text programmin