LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Catalog Download
MITSUBISHI RJ71GF11-T2 datasheet PDF catalog RJ71GF11-T2 PDF datasheet
Product model: RJ71GF11-T2
Name: IE Field CC-Link network module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Analog input channel number: 8CH.
Cold end compensation accuracy: plus or minus 1.
Available thermocouple: B, R, S, K, E, J, T, N.
Available temperature resistance: -.
Resolution 1:B, R, S, N:0.3
Resolution 2:K, E, J, T:0.1
Conversion speed: 30ms/CH.
Insulation between channels: isolation transformer insulation RJ71GF11-T2 datasheet PDF catalog RJ71GF11-T2 PDF datasheet.
Disconnection detection: there RJ71GF11-T2
External wiring connection mode: 40 pin connector.
output
The temperature measurement value (16 bit''signed binary): 2700 ~ 18200.
Zoom value (16 bit with symbol binary).
High speed data sampling is not affected by the scan time.
The analog input module has the function of recording, which can be used to collect the analog quantity input data in the industrial application RJ71GF11-T2 datasheet PDF catalog RJ71GF11-T2 PDF datasheet.
Can continuously collect data in a set period, each channel can store up to 10000 points of the recorded data.
In addition, the state of the state of any time and data in the program can be changed as a trigger,
To stop collecting data. The analog quantity input data can be stored and maintained before and after the trigger state through the function,
Easy to determine the occurrence of the phenomenon and the collection of test data RJ71GF11-T2 datasheet PDF catalog RJ71GF11-T2 PDF datasheet. Such as motor testing equipment used in this function.
Control instructions from a programmable controller to a transducer and a power meter transmission test mode,
At the same time, the test data of the test motor is collected at the same time. DC input, transistor (drain type) output.
Channel number: 2CH.
External wiring connection mode: 40 pin connector
Count input signal: there
Single phase input (single frequency / double frequency)
Dual phase input (single frequency and double frequency /4)
CW/CCW input: there
The signal level (phi A, Phi B): 2 ~ 5mA DC5/12/24V.
High sspeed counter module can be measured in 200kpulse/s when DC input,
8Mpulse/s measurement can be performed in a differential input RJ71GF11-T2 datasheet PDF catalog RJ71GF11-T2 PDF datasheet.
The use of high precision incremental encoder, the most suuitable for location tracking RJ71GF11-T2 datasheet PDF catalog RJ71GF11-T2 PDF datasheet.
In addition, the high-speed counter module is also equipped with a pulse measurement and PWM output and other functions.