LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Catalog Download
MITSUBISHI QX41-S2 datasheet PDF catalog QX41-S2 PDF datasheet
Product model: QX41-S2
Name: Type DC input module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
"2CH RS-232.
QJ71C24N (-R2) through the RS-232 serial communication,
Programming and monitoring of programmable controllers using programming tools.
QJ71C24N (-R2) with the function of the modem corresponding to the public telephone line,
Can be used to initialize the modem, and the connection of the object device processing,
Communication with a remote device, a programming tool, a modem, and a public telephone line QX41-S2 datasheet PDF catalog QX41-S2 PDF datasheet QX41-S2
Using remote password,
Can be prevented by QJ71C24N (-R2) function of the modem Q series programmable controller for illegal access.
Serial communication module capable of collecting and changing data of programmable controller, monitoring and managing, measuring data collection and so on QX41-S2 datasheet PDF catalog QX41-S2 PDF datasheet.
Can achieve the highest speed of 230.4kbps, the maximum of 960 words (MC protocol communications) of the high speed and large capacity communications.
Can use MC protocol, through the external devices (PC, monitors, etc.) to implement the data read / write programmable controller.
By selecting a non sequential protocol and use sequential program for communication control, the programmable controller and the external device (barcode reader and measurement equipment),
Communication with local protocols using external devices QX41-S2 datasheet PDF catalog QX41-S2 PDF datasheet. "Measurement items: leakage current (Io), resistive leakage current (Ior).
Measuring circuit number: 2 circuits.
Insulation monitoring module for measuring leakage current.
Leakage current can be measured to ensure safety by monitoring the leakage current (Io), can detect the risk of electric shock.
Insulation state measurement of resistive leakage current (Ior) can be monitored continuously and continuously,
In order to continuously monitor the insulation aging status of the equipment.
Each measurement project can be carried out in the 2 phase of the alarm monitoring can be respectively on the leakage current (Io), resistive leakage current (Ior) for the 2 phase of the alarm monitoring,
No ladder diagram program. Alarm monittoring is divided into 2 stages of attention alarm and danger alarm QX41-S2 datasheet PDF catalog QX41-S2 PDF datasheet.
A module can measure two circuits of a module can be two circuits on the same line in the same system type power measurement.
Inn addition, Works2 GX (1 QX41-S2 datasheet PDF catalog QX41-S2 PDF datasheet. 90U version or higher version) can be used to easily set the parameters.
Leakage current (Io), resistive leakage current (Ior).
Related products
MITSUBISHI
Input module
A1SX40-S2
MITSUBISHI Input module A1SX40-S2
Type of input: DC leakage. Input points:
MITSUBISHI
Temperature control module
A1S62TCRTBW-S2
MITSUBISHI Temperature control module A1S62TCRTBW-S2
Numer of channels: 2 channels. Sensing