LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Catalog Download
MITSUBISHI Q66AD-DG datasheet PDF catalog Q66AD-DG PDF datasheet
Product model: Q66AD-DG
Name: Current input analog module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Express PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station Q66AD-DG datasheet PDF catalog Q66AD-DG PDF datasheet Q66AD-DG
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network Q66AD-DG datasheet PDF catalog Q66AD-DG PDF datasheet.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q66AD-DG datasheet PDF catalog Q66AD-DG PDF datasheet.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.Input points: 32 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
32 points and 1 common ends.
Common anode.
Output points: 32 points.
Output voltage and current: DC12-24V; 0.1A/ point; 2A/ common.
Response time: 1ms.
1 point 32 public end, leakage type; 40 pin connector.
With thermal protection.
With short circuit protection.
With the surge absorber.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data transceiver time between the CPU module.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily displayed.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the eextension to the file register to all regions of the file register Q66AD-DG datasheet PDF catalog Q66AD-DG PDF datasheet.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured daata (array),
The speed has been improved Q66AD-DG datasheet PDF catalog Q66AD-DG PDF datasheet.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
Related products
MITSUBISHI
Current input analog module
Q66AD-DG
MITSUBISHI Current input analog module Q66AD-DG
8 channel. Input: DC420mA. Output reso