Board module installation location: QS series power module mounting slot.
Suitable substrate module: QS034B.
Input power: AC200~240V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system Q03UDCPU datasheet PDF catalog Q03UDCPU PDF datasheet
Q03UDCPU
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures Q03UDCPU datasheet PDF catalog Q03UDCPU PDF datasheet.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q03UDCPU datasheet PDF catalog Q03UDCPU PDF datasheet. Input: 4 channels.
Platinum resistance (Pt100; JPt100).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reachh the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q03UDCPU datasheet PDF catalog Q03UDCPU PDF datasheet.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q03UDCPU datasheet PDF catalog Q03UDCPU PDF datasheet.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.