Input points: 16 points.
Rated input voltage: DC24V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L6ADP-R2-CM datasheet PDF catalog L6ADP-R2-CM PDF datasheet L6ADP-R2-CM datasheet PDF catalog L6ADP-R2-CM PDF datasheet
L6ADP-R2-CM RS-232.
Transmission speed: 230.4kbps.
MC protocol.
Communication protocol support function.
Can only be used on the ch1 side.
Device for immediate communication
Communication protocol support function through Works2 GX,
Can easily set the required agreement with the other equipment communication L6ADP-R2-CM datasheet PDF catalog L6ADP-R2-CM PDF datasheet.
In addition, only the communication protocol library is required to select the equipment to be carried out,
Immediate connection.
The creation and editing of communication protocols are simple and easy to implement, even if there is no connection equipment in the communication protocol library,
Can also simply create a corresponding protocol for communication.
The content of the communication protocol that can be created in the list,
Can also be simply edited. "Universal output function: source type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet (built-in CC-Link function).
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for hhigh precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement L6ADP-R2-CM datasheet PDF catalog L6ADP-R2-CM PDF datasheet L6ADP-R2-CM datasheet PDF catalog L6ADP-R2-CM PDF datasheet.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "