No introductionOutput type: transistor output, drain type.
Output points: 4 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0 CL2XY16-DTP1C5V datasheet PDF catalog CL2XY16-DTP1C5V PDF datasheet. 3~1.5MM square.
Terminal block is 2 piece structure
CL2XY16-DTP1C5V
An input module shared by the common terminal of the positive and negative.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated input voltage / current: DC24V/4mA CL2XY16-DTP1C5V datasheet PDF catalog CL2XY16-DTP1C5V PDF datasheet.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Input type: DC input, positive public end / negative public end CL2XY16-DTP1C5V datasheet PDF catalog CL2XY16-DTP1C5V PDF datasheet.
Input points: 2 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: relay output.
Output points: 2 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A.
External connection: 2 line /2 line type.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 1 wire.
MIL connector type.
Minimumm size of industry CL2XY16-DTP1C5V datasheet PDF catalog CL2XY16-DTP1C5V PDF datasheet.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be reeplaced with a simple module CL2XY16-DTP1C5V datasheet PDF catalog CL2XY16-DTP1C5V PDF datasheet.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space.