Output type: transistor output, drain type.
Output points: 4 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square CL1Y2-T1D2S datasheet PDF catalog CL1Y2-T1D2S PDF datasheet.
Terminal block is 2 piece structure
CL1Y2-T1D2S
An input module shared by the common terminal of the positive and negative.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Input type: DC input, positive public end / negative public end.
Input points: 4 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA CL1Y2-T1D2S datasheet PDF catalog CL1Y2-T1D2S PDF datasheet.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square.
Terminal block is 2 piece structure.
An input module shared by the common terminal of the positive and negative.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Output type: transistor output, drain type.
Output points: 2 points CL1Y2-T1D2S datasheet PDF catalog CL1Y2-T1D2S PDF datasheet.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.1A.
External connection: 2 wire.
Cable type.
Minimum size of industry.
Can be like a cable, placed in the online slot.
The communication cable and the external equipment connecting cable is a type, and the wiring is simple.
Communication side, input and output side with cable (50cm). Input type: DC input, positive common end.
Input points: 4 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Output type: relay output.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A.
External coonnection: 1 wire CL1Y2-T1D2S datasheet PDF catalog CL1Y2-T1D2S PDF datasheet.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negativve pole CL1Y2-T1D2S datasheet PDF catalog CL1Y2-T1D2S PDF datasheet.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.