MITSUBISHI AJ65BT-D75P2-S3 datasheet PDF catalog AJ65BT-D75P2-S3 PDF datasheet
Product model: AJ65BT-D75P2-S3
Name: Positioning module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0 AJ65BT-D75P2-S3 datasheet PDF catalog AJ65BT-D75P2-S3 PDF datasheet. 5A.
External connection: 1 line /1 line type AJ65BT-D75P2-S3
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ65BT-D75P2-S3 datasheet PDF catalog AJ65BT-D75P2-S3 PDF datasheet. Bus connector conversion cable package10BASE2.
For Q mode.
Control layer /MELSECNET/10 (H) is the middle layer of the whole network system,
Control network which is convenient and high speed processing data transmission between PLC, CNC and other control equipment.
As MELSEC control network MELSECNET/10,
With its good real-time performance, simple network settings, no procedures of the network data sharing concept,
As well as the redundant circuit and so on, has obtained the very high market appraisal,
The number of devices to reach the highest in japan,
In the world is also one of the few AJ65BT-D75P2-S3 datasheet PDF catalog AJ65BT-D75P2-S3 PDF datasheet.
And MELSECNET/H not only inherited the excellent characteristics of MELSECNET/10,
Also makes the network real-time better, more data capacity,
Further adapt to the needs of the market. Adapter for mounting rails. Unit connection CPU unit.The use of A1STA32 can significantly reduce the wiring time I/O 32 type of connector assembly,
Neither welding, without thread stripping,
It only needs to cut a wire and insert the wire into the terminal hole of the A1STA32,
A1STA32 in the blade will cut wire insulation surface,
To make contact and hold a good conductor. Output points: 8 points.
Output voltage and current: AC100 ~ 240V, 2A/1 point, 5A/1 public end.
Response time: 0.5Hz+1ms.
Output form: bidirectional thyristor output.
8 point /1 a public side.
26 point terminal station.
Number of stations: 1 stops.
Type remote I/O unit (twisted pair data connection).
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved.
Q series PLC in the use of CC-Link function better,
And easier to use.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module has the function of Internet e-mail receeiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system AJ65BT-D75P2-S3 datasheet PDF catalog AJ65BT-D75P2-S3 PDF datasheet.
At the same time, tthe use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information AJ65BT-D75P2-S3 datasheet PDF catalog AJ65BT-D75P2-S3 PDF datasheet.
Related products
MITSUBISHI
Positioning control module
A1SD75P2-S3
MITSUBISHI Positioning control module A1SD75P2-S3
Axis of control: 2 axis linkage, 2 axis
MITSUBISHI
Temperature control module
AJ65BT-68RD3
MITSUBISHI Temperature control module AJ65BT-68RD3
Screw, 2 piece type terminal Platinum te
MITSUBISHI
RS-232 interface module (old model)
AJ65BT-R2
MITSUBISHI RS-232 interface module (old model) AJ65BT-R2
RS-232 1 channels. With DC input 2 point
MITSUBISHI
Analog output module
AJ65BT-64DAV
MITSUBISHI Analog output module AJ65BT-64DAV
Screw, 2 piece type terminal. Voltage ou