Product model: AJ35T-M08B-K
Name: Analog module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Category: slave station.
Transfer speed: 125kbps/250kbps/500kbps/1Mbps.
Transmission line form: bus system.
Total distance: 125kbps:1000m/250kbps:800m/500kbps:480m/1Mbps:240m.
The maximum connection units: 32.
Total points: input + output <=2048 point.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures AJ35T-M08B-K datasheet PDF catalog AJ35T-M08B-K PDF datasheet.
These procedures are relatively independent, generally in the basic completion of the program design and then add AJ35T-M08B-K
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. Enter points: 64 points.
Input voltage: DC7V above AJ35T-M08B-K datasheet PDF catalog AJ35T-M08B-K PDF datasheet.
Input response time: 16ms.
16 pin connector.
Output points: 64 points.
Output response time: 16ms.
Output type: transistor output.
32 pin connector.
Dynamic input and output.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AJ35T-M08B-K datasheet PDF catalog AJ35T-M08B-K PDF datasheet.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
Thee output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc AJ35T-M08B-K datasheet PDF catalog AJ35T-M08B-K PDF datasheet. .
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points AJ35T-M08B-K datasheet PDF catalog AJ35T-M08B-K PDF datasheet.
Related products
MITSUBISHI
Analog module
AJ35T-M12B-R
MITSUBISHI Analog module AJ35T-M12B-R
Analog channel: 12 channels. Input / out
MITSUBISHI
Analog module
AJ35T-M08B-K
MITSUBISHI Analog module AJ35T-M08B-K
Analog channel: 8 channels. Input / outp
MITSUBISHI
Analog module
AJ35T-M04B-K
MITSUBISHI Analog module AJ35T-M04B-K
Analog channel: 4 channels. Input / outp