I/O slots: 2 slots.
Outline dimension: 220*130.
CPU basic board can be plugged into 1 power modules,
1 CPU components and a maximum of 2, 3, 5, or 8 single slot size special function components and I/O components are respectively inserted and arranged.
The expansion port are arranged on the basic substrate on both sides, for connecting board for expansion A960GOT-EBD datasheet PDF catalog A960GOT-EBD PDF datasheet
A960GOT-EBD
Up to 3 extension substrates. Optional features of memory card (A/FX compatible).
4MB extended memory.
Applicable models: A985 (-V) /975/970/A960GOT (-B) /A956WGOT. Output type: relay output.
Output points: 16 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A.
External connection: 2 wire A960GOT-EBD datasheet PDF catalog A960GOT-EBD PDF datasheet.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Using a modem middle modular connector unit faces to transmit data transmission speed: 0 A960GOT-EBD datasheet PDF catalog A960GOT-EBD PDF datasheet. 3-14.4kbps.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, succh as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next rround of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work A960GOT-EBD datasheet PDF catalog A960GOT-EBD PDF datasheet A960GOT-EBD datasheet PDF catalog A960GOT-EBD PDF datasheet.