LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI QY71 Manual QY71 User's Manual
Product model: QY71
Name: I/O Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Three-phase 3 wire type.
Measuring circuit number: 4 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information QY71 Manual QY71 User's Manual QY71
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment QY71 Manual QY71 User's Manual.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk QY71 Manual QY71 User's Manual.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0.2.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program.
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment. Output points: 64 points.
Output voltage and current: 24V ~ 0.2A/1 DC5 point.
2A/1 common end.
OFF leakage current: 0.1mA.
Response time: 1ms.
32 points and 1 common ends.
Leaky type.
40 pin connector.
With heat protection.
With short circuit protection.
With the surge absorber.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data transceiver time between the CPU module QY71 Manual QY71 User's Manual.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily diisplayed QY71 Manual QY71 User's Manual.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Related products
MITSUBISHI
Input module
AX71
MITSUBISHI Input module AX71
Input points: 32 points. Voltage: DC5/12
MITSUBISHI
CMOS TTL output module
QY70
MITSUBISHI CMOS TTL output module QY70
Output points: 16 points. Output voltage
MITSUBISHI
Type DC input module
QX71
MITSUBISHI Type DC input module QX71
Input points: 32 points. Input voltage a