LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI QS034B-E Manual QS034B-E Safety Application Guide
Product model: QS034B-E
Name: PLC
Brand: MITSUBISHI
Sort: Safety Application Guide
File language: English
"2 axes, SSCNET connection type.
2 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
40 pin connector.
Easy to achieve high speed, high precision positioning control.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc QS034B-E Manual QS034B-E Safety Application Guide QS034B-E .
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug.
Saving wiring through SSCNET cable connections while simultaneously,
The length of the total cable distance up to 30m.
In addition, an absolute position system for determining the origin position is supported by the return data set operation of the origin QS034B-E Manual QS034B-E Safety Application Guide.
No need for the near point block, such as wiring. "Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module QS034B-E Manual QS034B-E Safety Application Guide.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reeach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs QS034B-E Manual QS034B-E Safety Application Guide.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process QS034B-E Manual QS034B-E Safety Application Guide.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
Safety bottom plate module
QS034B
MITSUBISHI Safety bottom plate module QS034B
The input and output module installation