LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI QJ71PB92V Manual QJ71PB92V User's Manual
Product model: QJ71PB92V
Name: PROFIBUS-DP Master Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
5 slots.
No need for power.
Used to install large Q series modules.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance QJ71PB92V Manual QJ71PB92V User's Manual QJ71PB92V
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Wider application range, more advanced.
Leading in the era of the Q series CPU products.
Q series CPU products a wide range of applications,
Provide programmable controller, process, redundancy, C language, movement, manipulator, CNC all kinds of CPU,
In order to meet the needs of various control QJ71PB92V Manual QJ71PB92V User's Manual.
Through the multi CPU configuration, can be based on the use of the scale, purpose,
Construction of the best system to meet the requirements of all kinds of control.
In addition, the high reliability system can be constructed by the redundant system,
Even if a fault occurs, the system can continue to run QJ71PB92V Manual QJ71PB92V User's Manual. Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Input and output points: 1024 points.
Input / output data points: 8192 points.
Program capacity: 60k.
Basic command processing speed (LD command) S:0.2.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler.
User program storage capacity: it is a measure of how much the usser application can store the number of indicators QJ71PB92V Manual QJ71PB92V User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words QJ71PB92V Manual QJ71PB92V User's Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
AS-i module
QJ71AS92
MITSUBISHI AS-i module QJ71AS92
Master station. Support AS interface spe
MITSUBISHI
MES interface module
QJ71MES96
MITSUBISHI MES interface module QJ71MES96
MES interface module. Need MX MESInterfa
MITSUBISHI
FL-net module
QJ71FL71-T-F01
MITSUBISHI FL-net module QJ71FL71-T-F01
FL-net OPCN-2 Ver.2.00 interface. 10BA