LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI QD77MS4 Positioning control Manual QD77MS4 User's Manual
Product model: QD77MS4
Name: Simple Motion Module
Brand: MITSUBISHI
Sort: Positioning control User's Manual
File language: English
FL-net (OPCN-2) Ver.2.00 interface.
10BASE5/10BASE-T use.
Real time transmission control data, to improve the production efficiency and the value of the equipment to provide support for the high-speed data communication module.
The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet QD77MS4 Positioning control Manual QD77MS4 User's Manual QD77MS4
Realize the previous communication method can not achieve the detailed control of data transmission,
Real time data analysis using user applications,
In order to provide support for improving production efficiency and equipment value.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings QD77MS4 Positioning control Manual QD77MS4 User's Manual. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.4 channel.
Input: DCO~20mA DC-10~10V QD77MS4 Positioning control Manual QD77MS4 User's Manual.
Output (resolution): 0~32000; -32000~32000; 0~64000; -64000~64000.
Conversion speed: 10ms/4 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need ffor an external isolation amplifier QD77MS4 Positioning control Manual QD77MS4 User's Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input modulee QD77MS4 Positioning control Manual QD77MS4 User's Manual.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
Related products