Input: 2 channels.
200/100/10kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
DC12/24V.
0.1A/ point.
0.4A/ common end.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application Q25PHCPU PID Control Instructions Manual Q25PHCPU Programming Manual
Q25PHCPU
High speed counter module for counting high-speed pulse train.
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge.
Each 1 channel is equipped with 2 points of external uniform output Q25PHCPU PID Control Instructions Manual Q25PHCPU Programming Manual .
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter function,
In order to meet the needs of various applications. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency) Q25PHCPU PID Control Instructions Manual Q25PHCPU Programming Manual .
Can be in the semiconductor, liquid crystal manufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders. (QD65PD2)Output points: 16 points.
Output voltage and current: DC12~24V; 0.5A/ point; 4A/ common.
OFF leakage current: 0.1mA.
Response time: 1ms.
16 points and 1 common ends.
Source type.
18 point spring clip connection terminal.
With the surge absorber.
With fuse.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data transceiver time between the CPU module.
Can be ussed to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily diisplayed Q25PHCPU PID Control Instructions Manual Q25PHCPU Programming Manual Q25PHCPU PID Control Instructions Manual Q25PHCPU Programming Manual .
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.