LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual
Product model: Q24DHCCPU-LS
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Manual
File language: English
Program capacity: 124 K step.
Input / output points: 4096 points.
Number of input and output elements: 8192.
Processing speed: 0.034 s.
Program memory capacity: 496 KB.
Support USB and RS232.
High performance CPU plus a set of rich and powerful process control instructions.
High speed and high precision machine control by multi CPU Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual Q24DHCCPU-LS
By parallel processing of the linear and multi CPU high-speed communication (cycle 0.88ms) of the parallel control program, the high speed control.
Multi CPU high speed communication cycle and motion control synchronization, so it can achieve the maximization of computing efficiency.
In addition, the latest movement control CPU in performance is 2 times the previous model,
To ensure high speed and high accuracy of the machine control Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual.
The position signal of the first axis servo amplifier, which is used on the motion CPU, is used as a trigger,
Starting from the programmable controller CPU to the second axis servo amplifier,
Time to output speed command of servo amplifier.
This time is the index of data transmission speed between CPU.Input: 4 channels.
Platinum resistance (Pt100; JPt100) Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual.
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set valuee at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
C language CPU
Q24DHCCPU-LS
MITSUBISHI C language CPU Q24DHCCPU-LS