Output points: 16 points.
Output voltage and current: 24V/AC240V 2A/1; DC point; 8A/1 common end.
Response time: 12ms.
16 points / a common end.
18 point spring clip connection terminal.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password Maintenance and Inspection Manual Q173NCCPU User's Manual.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password
Q173NCCPU
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights Maintenance and Inspection Manual Q173NCCPU User's Manual.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields Maintenance and Inspection Manual Q173NCCPU User's Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.Master / local station sharing.
Corresponding Ver2 CC-Link.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affeect the link scan time Q173NCCPU Hardware Design.
The QJ61BT11N module supports CC-Link version 1 and version 2, which can be used as a local station or master station module.
I/O control in the first class of open field network module.
CC-Link baseed on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q173NCCPU Hardware Design.