Compact flash memory card.
Capacity: 1GB bytes.Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA.
Conversion speed (output):25ms/2 channel.
18 point terminal station.
With 5 kinds of PID control mode Q13UDVCPU Structured Text Manual Q13UDVCPU Programming Guide.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc
Q13UDVCPU.
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response Q13UDVCPU Structured Text Manual Q13UDVCPU Programming Guide.
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analog.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integration time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station Q13UDVCPU Structured Text Manual Q13UDVCPU Programming Guide. FL-net (OPCN-2) Ver.2.00 interface.
10BASE5/10BASE-T use.
Real time transmission control data, to improve the production efficiency and the value of the equipment to provide support for the high-speed data communication module.
The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet.
Realize the previous communication method can not achieve the detailed control of data transmission,
Real time data analysis using user applications,
In order to provide support for improving production efficiency and equipment value.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connectioon (1 to 1),
No need to carry out the IP address settings Q13UDVCPU Structured Text Manual Q13UDVCPU Programming Guide. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q13UDVCPU Structured Text Manual Q13UDVCPU Programming Guide.