Control axis: maximum 8 axes.
Peripheral I/F: by CPU PLC.
Manual pulse generator operation function: can use 3 sets of manual pulse generator.
Synchronous encoder operation function: can use 8 synchronous encoder.
CPU special high speed communication bus, each 0.88ms cycle can exchange 14K data word Q12DCCPU-CBL Application Functions Manual Q12DCCPU-CBL Programming Manual.
Exercise basic performance is about 2 times, sports SFC processing time is reduced by about 1/4
Q12DCCPU-CBL
PLC interrupt program to achieve high-speed synchronization between multiple CPU.
Motion specific instruction.1 axis, differential drive output type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 1Mpps.
40 pin connector.
Positioning module.
Open collector output Q12DCCPU-CBL Application Functions Manual Q12DCCPU-CBL Programming Manual.
Differential driver output.
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs Q12DCCPU-CBL Application Functions Manual Q12DCCPU-CBL Programming Manual.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications.
Based on the use of open collector outputs and differential drive output tyype 2 types Q12DCCPU-CBL Application Functions Manual Q12DCCPU-CBL Programming Manual.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q12DCCPU-CBL Application Functions Manual Q12DCCPU-CBL Programming Manual.
(the command pulse of the open collector positioning module is highest 200kpps.)