Extended SRAM card 1MB.
Support SD memory card.
High speed universal QCPU support SD memory card,
In order to be able to have a memory card port between SD and PC to easily realize data exchange.
In addition, the SD memory card and the extended SRAM card can be used simultaneously.
Therefore, the extension of the file register using the extended SRAM card,
SD memory card can be used at the same time to carry out the data file record, a large number of annotation data storage, through the memory card to guide operation Q10UDHCPU Structured Text(ST) Manual Q10UDHCPU PROGRAMMING Guide Book
Q10UDHCPU Input / output points: 4096 points.
Size side mode: small end mode.
SD memory card: available.
6.8.1 OS:VxWorks edition.
Advanced information processing and stable I/O control of high-end type Q10UDHCPU Structured Text(ST) Manual Q10UDHCPU PROGRAMMING Guide Book.
C language controller is a long term stable supply, high reliability, high performance, flexible MELSEC on the implementation of the C language program revolutionary open platform.
Including pre installed VxWorks,
This C language controller can be used with various modules of the MELSEC-Q series,
Partner products and open source,
Client program assets, such as portfolio use to build a variety of systems Q10UDHCPU Structured Text(ST) Manual Q10UDHCPU PROGRAMMING Guide Book.
As can be used in all scenarios, can replace the computer, a new computer platform,
C MELSEC language controller stronger, simpler, higher performance, more flexible, in the future will also continue to continue to develop.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value att the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q10UDHCPU Structured Text(ST) Manual Q10UDHCPU PROGRAMMING Guide Book.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q10UDHCPU Structured Text(ST) Manual Q10UDHCPU PROGRAMMING Guide Book.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.