MITSUBISHI Q10UDHCPU Common Instructions Manual Q10UDHCPU Strctured Programming Manual
Product model: Q10UDHCPU
Name: CPU
Brand: MITSUBISHI
Sort: Common Instructions Strctured Programming Manual
File language: English
PCI bus.
Support Japanese, English OS.
3C-2V/5C-2V coaxial cable.
Single bus controller network (control station / common station).
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2 Q10UDHCPU Common Instructions Manual Q10UDHCPU Strctured Programming Manual Q10UDHCPU 5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q10UDHCPU Common Instructions Manual Q10UDHCPU Strctured Programming Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.Input and output points: 1024 points.
Input / output data points: 8192 points Q10UDHCPU Common Instructions Manual Q10UDHCPU Strctured Programming Manual.
Program capacity: 60k.
Basic command processing speed (LD command) S:0.2.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program.
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment. HHigh performance type CPU, process CPU, memory card protection cover for redundant CPU Q10UDHCPU Common Instructions Manual Q10UDHCPU Strctured Programming Manual.
Q3MEM-4MBS-SET bundled products.5 slots; requires 1 AnS series PLC power modules;
Useed to install large AnS series PLC module Q10UDHCPU Common Instructions Manual Q10UDHCPU Strctured Programming Manual.
Base plate of AnS series PLC.
QA1S series PLC 5 slot main substrate.
AnS series of modules can be installed.
Related products
MITSUBISHI
With Ethernet CPU
Q20UDEHCPU
MITSUBISHI With Ethernet CPU Q20UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
Moving CPU unit
A173UHCPU
MITSUBISHI Moving CPU unit A173UHCPU
CPU:A3UCPU PLC is the same. PLC program
MITSUBISHI
High performance CPU
Q06HCPU
MITSUBISHI High performance CPU Q06HCPU
Program capacity: 60 K step. Input / out