MITSUBISHI Q03UDECPU Special Instructions Manual Q03UDECPU Programming Manual
Product model: Q03UDECPU
Name: PLC
Brand: MITSUBISHI
Sort: Special Instructions Programming Manual
File language: English
Input: 8 channels.
30kpps/10kpps/1kpps/100pps/50pps/10pps/1pps/0.1pps.
Counter input signal: DC5/12-24V.
The module is suitable for the measurement of the number of input pulses, such as speed, speed, instantaneous flow rate and so on,
As well as the quantity, the length, the cumulative flow and so on the measurement Q03UDECPU Special Instructions Manual Q03UDECPU Programming Manual.
Input pulse values are updated every 10ms Q03UDECPU
The number of pulses (sampling pulse number), which can be accumulated and processed by the moving average, is updated according to the counting period. PCI bus.
Support Japanese, English OS.
3C-2V/5C-2V coaxial cable.
Single bus controller network (control station / common station).
Province distribution network module in cabinet and device Q03UDECPU Special Instructions Manual Q03UDECPU Programming Manual.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module Q03UDECPU Special Instructions Manual Q03UDECPU Programming Manual.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.Input voltage range: AC100-120V/AC200-240V.
Output voltage: DC5V.
Output power: 8.5A.
Simplified program debugging
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion Q03UDECPU Special Instructions Manual Q03UDECPU Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.
Through the expansion of soft components,, more convenient to create the program Q03UDECPU Special Instructions Manual Q03UDECPU Programming Manual.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Related products
MITSUBISHI
General purpose CPU
Q03UDCPU
MITSUBISHI General purpose CPU Q03UDCPU
Input / output points: 4096 points. Num
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Inpu
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Num