LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI Q02HCPU PID Control Instructions Manual Q02HCPU Programming Manual
Product model: Q02HCPU
Name: PLC
Brand: MITSUBISHI
Sort: PID Control Instructions Programming Manual
File language: English
Input: 2 channels.
4Mpps.
Counter input signal: EIA standard RS-422-A (differential linear drive).
External input: DC24V.
Uniform output: Transistor (drain type).
DC12/24V.
0.5A/ point.
2A/ common end.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application Q02HCPU PID Control Instructions Manual Q02HCPU Programming Manual Q02HCPU
High speed counter module for counting high-speed pulse train.
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge.
Each 1 channel is equipped with 2 points of external uniform output Q02HCPU PID Control Instructions Manual Q02HCPU Programming Manual.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter function,
In order to meet the needs of various applications Q02HCPU PID Control Instructions Manual Q02HCPU Programming Manual. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency).
Can be in the semiconductor, liquid crystal manufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders. (QD65PD2)Control axis: maximum 32 axes.
Teaching operation function: No.
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After starting the specified location to stop the instruction,,
Can be set in advance to stop the location Q02HCPU PID Control Instructions Manual Q02HCPU Programming Manual.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / decelleration time Q02HCPU PID Control Instructions Manual Q02HCPU Programming Manual.
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.
Related products
MITSUBISHI
CPU component
A1SJHCPU
MITSUBISHI CPU component A1SJHCPU
I/O control method: refresh mode or dire
MITSUBISHI
CPU unit
A2ASCPU
MITSUBISHI CPU unit A2ASCPU
I/O points: 512. Processing speed: sec/
MITSUBISHI
Programmable logic controller CPU
R120ENCPU
MITSUBISHI Programmable logic controller CPU R120ENCPU
Operation control mode: stored procedure
MITSUBISHI
General purpose CPU
Q10UDHCPU
MITSUBISHI General purpose CPU Q10UDHCPU
Input / output points: 4096 points. Num