LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI Q02HCPU-A Common Instructions Manual Q02HCPU-A Programming Manual
Product model: Q02HCPU-A
Name: Programmable Logic Controller
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
8 axis, differential drive output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 4Mpps.
40 pin connector.
Differential output.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing Q02HCPU-A Common Instructions Manual Q02HCPU-A Programming Manual Q02HCPU-A
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q02HCPU-A Common Instructions Manual Q02HCPU-A Programming Manual .
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q02HCPU-A Common Instructions Manual Q02HCPU-A Programming Manual .
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set valuue at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q02HCPU-A Common Instructions Manual Q02HCPU-A Programming Manual .
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q02HCPU-A Common Instructions Manual Q02HCPU-A Programming Manual .
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
A mode Q series CPU
Q02HCPU-A
MITSUBISHI A mode Q series CPU Q02HCPU-A
Input / output points: 4096 points. Num
MITSUBISHI
A mode Q series CPU
Q02CPU-A
MITSUBISHI A mode Q series CPU Q02CPU-A
Input / output points: 4096 points. Num
MITSUBISHI
High performance CPU
Q02HCPU
MITSUBISHI High performance CPU Q02HCPU
Program capacity: 28K step. Input / outp
MITSUBISHI
A mode Q series CPU
Q06HCPU-A
MITSUBISHI A mode Q series CPU Q06HCPU-A
Input / output points: 4096 points. Num