SRAM memory card.
RAM capacity: 512KB. Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording Q02CPU-A Structured Text Manual Q02CPU-A Programming Guide Book
Q02CPU-A
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance Q02CPU-A Structured Text Manual Q02CPU-A Programming Guide Book.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function Q02CPU-A Structured Text Manual Q02CPU-A Programming Guide Book.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set vaalue at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q02CPU-A Structured Text Manual Q02CPU-A Programming Guide Book.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q02CPU-A Structured Text Manual Q02CPU-A Programming Guide Book.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.