MITSUBISHI Q01CPU Application Manual Q01CPU User's Manual
Product model: Q01CPU
Name: PLC
Brand: MITSUBISHI
Sort: Application User's Manual
File language: English
Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 6A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action Q01CPU Application Manual Q01CPU User's Manual Q01CPU
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program Q01CPU Application Manual Q01CPU User's Manual.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion Q01CPU Application Manual Q01CPU User's Manual.
The next time the power is turned on, the backup data will be automatically restored.Measurement items: leakage current (Io), resistive leakage current (Ior).
Measuring circuit number: 2 circuits.
Insulation monitoring module for measuring leakage current.
Leakage current can be measured to ensure safety by monitoring the leakage current (Io), can detect the risk of electric shock.
Insulation state measurement of resistive leakage current (Ior) can be monitored continuously and continuously,
In order to continuously monitor the insulation aging status of the equipment.
Each measurement project can be carried out in the 2 phase of the alarm monitoring can be respectively on the leakage current (Io), resistive leakage current (Ior) for the 2 phase of the alarm monitoring,
No ladder diagram program. Alarm monitoring is divided into 2 stages of attention alarm and danger alarm Q01CPU Application Manual Q01CPU User's Manual.
A module can measure two circuits of a module can be two circuits on the same line in the same system type power measurement.
Inn addition, Works2 GX (1 Q01CPU Application Manual Q01CPU User's Manual. 90U version or higher version) can be used to easily set the parameters.
Leakage current (Io), resistive leakage current (Ior).
Related products
MITSUBISHI
CPU unit
Q2ASCPU
MITSUBISHI CPU unit Q2ASCPU
Input and output points: 512 points. Inp
MITSUBISHI
Programmable logic controller CPU
R04CPU
MITSUBISHI Programmable logic controller CPU R04CPU
Operation control mode: stored procedure
MITSUBISHI
General purpose CPU
Q04UDHCPU
MITSUBISHI General purpose CPU Q04UDHCPU
Input / output points: 4096 points. Num
MITSUBISHI
CPU unit
A3VCPU
MITSUBISHI CPU unit A3VCPU
Multiple CPU units for A3VTS multiplex s