Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 100 K step.
Processing speed: 0.0095 s.
Program memory capacity: 400 KB.
Support USB and RS232.
Support installed memory card.
Providing high speed communication between multiple CPU.
High speed and high precision data processing Q00UJCPU-S8-SET Application Functions Manual Q00UJCPU-S8-SET Programming Manual
Q00UJCPU-S8-SET
The processing speed of the real number (floating point) arithmetic has been greatly improved,
Addition instruction reached 0.014 mu s,
Therefore, it can support the request of high-speed, high-precision processing data processing.
In addition, the new addition of double precision floating point arithmetic instructions,
Simplify the programming, reduces the computational error when executing complex formula Q00UJCPU-S8-SET Application Functions Manual Q00UJCPU-S8-SET Programming Manual.
Shorten the fixed scan interrupt time, high precision device.
The minimum interval of the fixed period interrupt program is reduced to 100 s.
The high speed signal can be accurately obtained, which makes the contribution to the higher precision of the device.PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station) Q00UJCPU-S8-SET Application Functions Manual Q00UJCPU-S8-SET Programming Manual.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1 Q00UJCPU-S8-SET Application Functions Manual Q00UJCPU-S8-SET Programming Manual. 2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Linkk/LT from the station does not need any parameter settings Q00UJCPU-S8-SET Application Functions Manual Q00UJCPU-S8-SET Programming Manual.
Only need to set up the transmission speed in the master module, you can use the remote I/O.