LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI Q00UCPU Common Instructions Manual Q00UCPU Programming Manual
Product model: Q00UCPU
Name: PLC
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
8 axis, differential drive output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 4Mpps.
40 pin connector.
Differential output.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing Q00UCPU Common Instructions Manual Q00UCPU Programming Manual Q00UCPU
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q00UCPU Common Instructions Manual Q00UCPU Programming Manual.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q00UCPU Common Instructions Manual Q00UCPU Programming Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown. "The most common station 11 units connected network: 121.
The 11 largest network connection units security station: 32.
Maximum network number: 239 sets.
Maximum secure connection of 1 units: 31 connection.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the commponents in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q00UCPU Common Instructions Manual Q00UCPU Programming Manual Q00UCPU Common Instructions Manual Q00UCPU Programming Manual. "
Related products
MITSUBISHI
Programmable logic controller CPU
R120ENCPU
MITSUBISHI Programmable logic controller CPU R120ENCPU
Operation control mode: stored procedure
MITSUBISHI
Motion CPU module
Q172DCPU
MITSUBISHI Motion CPU module Q172DCPU
Control axis: maximum 8 axes. Peripheral
MITSUBISHI
Process CPU
Q25PHCPU
MITSUBISHI Process CPU Q25PHCPU
Program capacity: 252 K step. Input / ou
MITSUBISHI
Small points with substrate CPU
Q00UJCPU-S8-SET
MITSUBISHI Small points with substrate CPU Q00UJCPU-S8-SET
Upgrade payments. Input / output points: