5 slots.
The main substrate needs to be equipped with CPU and power supply.
Requires 1 power modules.
Used to install Q series modules.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module Q00JCPU-SET Application Manual Q00JCPU-SET User's Manual.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields
Q00JCPU-SET
Can also be used in combination with the CPU module to achieve appropriate control.8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A Q00JCPU-SET Application Manual Q00JCPU-SET User's Manual.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc..
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored Q00JCPU-SET Application Manual Q00JCPU-SET User's Manual.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddenly change.
By detecting the transient ppeak current at this time, the fault of the equipment can be diagnosed Q00JCPU-SET Application Manual Q00JCPU-SET User's Manual.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) Q00JCPU-SET Application Manual Q00JCPU-SET User's Manual.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.