MITSUBISHI MR-J3-20T CC-Link Manual MR-J3-20T INSTRUCTION MANUAL
Product model: MR-J3-20T
Name: SERVO AMPLIFIER
Brand: MITSUBISHI
Sort: CC-Link INSTRUCTION MANUAL
File language: English
MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 37.0kw.
Universal interface.
Voltage: 3 phase AC400V.
Super function, excellent performance.
High performance CPU integration, greatly improve product responsiveness.
Due to the application of high performance CPU, so that the response can be greatly improved MR-J3-20T CC-Link Manual MR-J3-20T INSTRUCTION MANUAL.
Speed loop frequency response increased to more than 550HZ MR-J3-20T
MR-J2-Super series is the best device for high speed positioning applications.
Easy adjustment.
Model adaptive control / advanced real time automatic tuning.
Mechanical analysis function.
Can analysis of the frequency characteristics of the mechanical system, the results can be easily set up "mechanical resonance suppression filter"
Mechanical simulation function MR-J3-20T CC-Link Manual MR-J3-20T INSTRUCTION MANUAL.
The function can be realized without the actual replacement of the motor. Read mechanical analysis results to simulate the response of the user''s mechanical system.Length: 3 meters.
Purpose: MR-JE-A. Drive: MR-H_ACN series CC-LINK features.
Rated output: 11KW.
The test system is composed of two parts, namely, the servo driver, the motor system and the host computer MR-J3-20T CC-Link Manual MR-J3-20T INSTRUCTION MANUAL.
The host computer sends the speed command signal to the servo driver,
Servo drives start to run in accordance with the instructions.
In the course of operation, the running data of the servo system is collected by the host computer and the data acquisition circuit,
And carries on the preservation, the analysis and the display to the data. Because the motor is not loaded in this test system,
So compared with the previous two kinds of testing systems, the system has a relatively small volume,
And the measurement and control circuuit of the system is relatively simple,
But it also makes the system can not simulate the actual operation of the servo drive MR-J3-20T CC-Link Manual MR-J3-20T INSTRUCTION MANUAL.
Usually, such testing system is only used to test the rotational speeed and angular displacement of the tested system under no-load condition,
And can not carry on the comprehensive and accurate test to the servo drive MR-J3-20T CC-Link Manual MR-J3-20T INSTRUCTION MANUAL.