"IE Field CC-Link master / local station
Transmission speed: 1Gbps.
Remote input / output: 16384 points.
Remote register: 8192 words.
Can be applied to the serial number of the top 5 for the "13012" and after the CPU module.
Simply set the parameters, you can easily start the network.
Simply use the Works2 GX, set the network parameters in the 1 master station, you can easily connect all the slave stations L02SCPU-P Structured Text Manual L02SCPU-P Programming Guide
L02SCPU-P
Also, when you need to change the system, you only need to change the parameters.
High degree of freedom network
Build star, linear, star and linear mixed model, and ring network,
Therefore, can freely set the scene equipment.
When you use HUB, you just need to connect the cable to the free port to build the network easily,
Additional equipment and re layout of the corresponding is also more simple L02SCPU-P Structured Text Manual L02SCPU-P Programming Guide. "Transmission speed: 100Mbps/10Mbps.
MELSOFT connection.
SLMP cross letter (MC protocol).
Communication protocol support function.
E-mail function.
Web function.
Collect / change CPU module data from the other side of the device.
SLMP (MC protocol) communication
SLMP is a protocol that uses Ethernet to access SLMP devices from the other device L02SCPU-P Structured Text Manual L02SCPU-P Programming Guide.
If it is possible to follow the SLMP control procedures to send and receive messages to the device,
The communication can be carried out by SLMP. MC can also support the previous agreement.
MELSOFT connection
Can be connected with the programming tool Works2 GX and other MELSOFT products.
In addition, through the use of communication tools to support the sale of (MX Component),
Regardless of the details of the protocol (how to send and receive procedures),
Can create a communication program on the upper side of the system.
It can easily connect to BACnet and MODBUS /TCP
Communication protocol support function
Through the Works2 GX communication protocol support function, can easily set the communication with the other equipment required for the agreement. Input points: 16 points.
Rated input voltage: AC100 ~ 120V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L02SCPU-P Structured Text Manual L02SCPU-P Programming Guide L02SCPU-P Structured Text Manual L02SCPU-P Programming Guide.