MITSUBISHI L02CPU-P Structured Text(ST) Manual L02CPU-P PROGRAMMING Guide Book
Product model: L02CPU-P
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text(ST) PROGRAMMING Guide Book
File language: English
Enter points: 64 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: 64 points).
External wiring connection: 40 pin connector two.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L02CPU-P Structured Text(ST) Manual L02CPU-P PROGRAMMING Guide Book L02CPU-P Structured Text(ST) Manual L02CPU-P PROGRAMMING Guide Book L02CPU-P Number of input channels: 2Ch.
Differential drive input.
Maximum count rate: pulse/s 500K.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function L02CPU-P Structured Text(ST) Manual L02CPU-P PROGRAMMING Guide Book.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized. Differential output.
Axis of control: 4.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time.
Monitorring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check L02CPU-P Structured Text(ST) Manual L02CPU-P PROGRAMMING Guide Book.
Can only choose the necessary items from the rich monitoring information and monitor the display L02CPU-P Structured Text(ST) Manual L02CPU-P PROGRAMMING Guide Book.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.
Related products
MITSUBISHI
cpu module
L02CPU-CM
MITSUBISHI cpu module L02CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type.
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type.