LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI FX3UC-32MT/D Positioning Control Edition Manual FX3UC-32MT/D USER'S MANUAL
Product model: FX3UC-32MT/D
Name: PLC
Brand: MITSUBISHI
Sort: Positioning Control Edition USER'S MANUAL
File language: English
Max input / output points: 48 points.
Supply voltage: 100 - 240VAC.
Input points: 24 points.
Output points: 24 points.
Output type: silicon controlled.
Power consumption: 50VA.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FX3UC-32MT/D Positioning Control Edition Manual FX3UC-32MT/D USER'S MANUAL FX3UC-32MT/D
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K FX3UC-32MT/D Positioning Control Edition Manual FX3UC-32MT/D USER'S MANUAL.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable FX3UC-32MT/D Positioning Control Edition Manual FX3UC-32MT/D USER'S MANUAL.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program"MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 30KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX3UC-32MT/D Positioning Control Edition Manual FX3UC-32MT/D USER'S MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX3UC-32MT/D Positioning Control Edition Manual FX3UC-32MT/D USER'S MANUAL. "
Related products
MITSUBISHI
Analog input module
FX3UC-4AD
MITSUBISHI Analog input module FX3UC-4AD
Power supply: 110mA DC5V PLC internal p
MITSUBISHI
PLC
FX5UC-32MT/D
MITSUBISHI PLC FX5UC-32MT/D
Function: CPU module. Input and output p
MITSUBISHI
PLC
FX3UC-96MT/D
MITSUBISHI PLC FX3UC-96MT/D
Input and output points: 96 points. Inpu
MITSUBISHI
PLC
FX3UC-32MT/D
MITSUBISHI PLC FX3UC-32MT/D
Input and output points: 32 points. Inpu