LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI FX3U-CNV-BD Manual FX3U-CNV-BD INSTALLATION MANUAL
Product model: FX3U-CNV-BD
Name: function expansion board
Brand: MITSUBISHI
Sort: INSTALLATION MANUAL
File language: English
Voltage input: DC-10~10V.
Current input: DC0~20mA.
Channel number: 4 channel analog output.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
Resolution of 11 bit binary + symbol 1 (voltage), 10 bit binary (current) high precision analog output module FX3U-CNV-BD Manual FX3U-CNV-BD INSTALLATION MANUAL.
Voltage output and current output of 4 channels can be carried out FX3U-CNV-BD
Can be specified for each channel voltage or current output. Can be connected to the models: FX3SA, FX3S, FX3GA, FX3G, FX3GE.
Interface: RJ45 connector.
Weight: 0.02kg.
Can be equipped with the RS-485 communication function of the external equipment.
Carrying the RS-485 communication function between the PLC for communication FX3U-CNV-BD Manual FX3U-CNV-BD INSTALLATION MANUAL. Max input / output points: 20 points.
Power supply voltage: DC24V.
Input points: 12 points.
Output points: 8 points.
Output type: Transistor (source).
Power consumption (W): 20.
Weight (kg):0.4.
Size (WxHxD) mm:75x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control FX3U-CNV-BD Manual FX3U-CNV-BD INSTALLATION MANUAL.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. Max input / output points: 128 points.
Power supply voltage: DC24V.
Input points: 64 points.
Output points: 64 points.
Output type: transistor.
Power consumption: 100VA.
Weight (kg):1.8.
Size (WxHxD) mm:350x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to tthe input and output expansion modules and special function modules FX3U-CNV-BD Manual FX3U-CNV-BD INSTALLATION MANUAL.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable FX3U-CNV-BD Manual FX3U-CNV-BD INSTALLATION MANUAL.
Related products
MITSUBISHI
PLC
FX3U-128MT/ES-A
MITSUBISHI PLC FX3U-128MT/ES-A
Max input / output points: 128 points. S
MITSUBISHI
Expansion board
FX1N-CNV-BD
MITSUBISHI Expansion board FX1N-CNV-BD
Extension oard for connection with spec
MITSUBISHI
CF special adapter
FX3U-CF-ADP
MITSUBISHI CF special adapter FX3U-CF-ADP
Maximum file size: 512MB. Data form: CSV