MITSUBISHI FX3U-64MT/DSS Basic & Applied Instructions Edition Manual FX3U-64MT/DSS PROGRAMMING MANUAL
Product model: FX3U-64MT/DSS
Name: PLC
Brand: MITSUBISHI
Sort: Basic & Applied Instructions Edition PROGRAMMING MANUAL
File language: English
Application: a write device (with a built-in flash memory) that is not required to use a similar ROM writer,
GOT can be carried out between the fast and simple picture data transmission.
Application Series: F940WGOT, F940GOT. Output: 16 points.
Function: relay output.
Corresponding models: FX3GA, FX3G, FX3GE, FX3GC, FX3U, FX3UC FX3U-64MT/DSS Basic & Applied Instructions Edition Manual FX3U-64MT/DSS PROGRAMMING MANUAL FX3U-64MT/DSS
Can carry on the FX3GC, the FX3UC basic unit and the expansion module or the localization module the connector and the terminal station transformation,
Save the time of the input and output connection, realize the labor saving.
The use of built-in input and output components models,
Can receive AC100V input, or through the relay or the transistor to drive large capacity load FX3U-64MT/DSS Basic & Applied Instructions Edition Manual FX3U-64MT/DSS PROGRAMMING MANUAL. Memory format: flash memory.
Number of steps: up to 16000 steps.
Battery support: do not.
Write, delete method: installed on the PLC through the peripheral devices to write, delete. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Power: 0.4kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted FX3U-64MT/DSS Basic & Applied Instructions Edition Manual FX3U-64MT/DSS PROGRAMMING MANUAL.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. Power: 30kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and abovve capacity FX3U-64MT/DSS Basic & Applied Instructions Edition Manual FX3U-64MT/DSS PROGRAMMING MANUAL.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motorr power used to select the DC reactor FX3U-64MT/DSS Basic & Applied Instructions Edition Manual FX3U-64MT/DSS PROGRAMMING MANUAL.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)
Related products
MITSUBISHI
PLC
FX3UC-16MT/DSS
MITSUBISHI PLC FX3UC-16MT/DSS
Input and output points: 16 points. Inpu
MITSUBISHI
PLC
FX3G-60MT/DSS
MITSUBISHI PLC FX3G-60MT/DSS
Input and output points: 60 points. Powe
MITSUBISHI
PLC
FX3G-14MT/DSS
MITSUBISHI PLC FX3G-14MT/DSS
Input and output points: 14 points. Powe