LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI FX3U-32MT/DSS Hardware Edition Manual FX3U-32MT/DSS USER'S MANUAL
Product model: FX3U-32MT/DSS
Name: PLC
Brand: MITSUBISHI
Sort: Hardware Edition USER'S MANUAL
File language: English
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Power: 110kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function FX3U-32MT/DSS Hardware Edition Manual FX3U-32MT/DSS USER'S MANUAL FX3U-32MT/DSS Max input / output points: 30 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 14 points.
Output type: relay.
Power consumption (W): 21.
Weight (kg):0.45.
Size (WxHxD) mm:100x90x75.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device FX3U-32MT/DSS Hardware Edition Manual FX3U-32MT/DSS USER'S MANUAL.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FX3U-32MT/DSS Hardware Edition Manual FX3U-32MT/DSS USER'S MANUAL.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 45KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
If the given acceleration time is too short, the output frequency of the inverter is far more than the change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 15.0kw.
SLD converter rated current: 31.0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor FX3U-32MT/DSS Hardware Edition Manual FX3U-32MT/DSS USER'S MANUAL.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control FX3U-32MT/DSS Hardware Edition Manual FX3U-32MT/DSS USER'S MANUAL.
Related products
MITSUBISHI
PLC
FX3U-32MT/DSS
MITSUBISHI PLC FX3U-32MT/DSS
Max input / output points: 32 points. Po
MITSUBISHI
PLC
FX3GE-40MT/DSS
MITSUBISHI PLC FX3GE-40MT/DSS
Input and output points: 40 points. Powe
MITSUBISHI
PLC
FX3GC-32MT/DSS
MITSUBISHI PLC FX3GC-32MT/DSS
Input and output points: 32 points. Powe
MITSUBISHI
PLC
FX3U-32MT/ESS
MITSUBISHI PLC FX3U-32MT/ESS
Max input / output points: 32 points. Su