MITSUBISHI FX3GA-60MT-CM Basic & Applied Instructions Edition Manual FX3GA-60MT-CM PROGRAMMING MANUAL
Product model: FX3GA-60MT-CM
Name: PLC
Brand: MITSUBISHI
Sort: Basic & Applied Instructions Edition PROGRAMMING MANUAL
File language: English
MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 630KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor FX3GA-60MT-CM Basic & Applied Instructions Edition Manual FX3GA-60MT-CM PROGRAMMING MANUAL FX3GA-60MT-CM
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor FX3GA-60MT-CM Basic & Applied Instructions Edition Manual FX3GA-60MT-CM PROGRAMMING MANUAL.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity. Connecting cable for handheld GOT and PLC.
Cable length: 3 meters.
Application: RS-422 connection. Input and output points: 24 points.
Power supply: DC24V.
Input points: 14 points.
Output points: 10 points.
Output form: transistor output (source) FX3GA-60MT-CM Basic & Applied Instructions Edition Manual FX3GA-60MT-CM PROGRAMMING MANUAL.
Power consumption: 21W.
Weight: 0.55KG.
Outline dimension: 90x90x86mm.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features.
Applicable to a wide variety of applications.
Basic unit: 24/40 point.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
A versatile PLC.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 55kw.
SLD converter rated current: 116A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor.
In the state of the sensor can not only drive the high efficiiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor) FX3GA-60MT-CM Basic & Applied Instructions Edition Manual FX3GA-60MT-CM PROGRAMMING MANUAL.
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FX3GA-60MT-CM Basic & Applied Instructions Edition Manual FX3GA-60MT-CM PROGRAMMING MANUAL.
Related products
MITSUBISHI
PLC
FX3GA-60MR-CM
MITSUBISHI PLC FX3GA-60MR-CM
Input and output points: 60 points. Powe
MITSUBISHI
PLC
FX3SA-30MT-CM
MITSUBISHI PLC FX3SA-30MT-CM
Input and output points: 30 points. Powe
MITSUBISHI
PLC
FX3GA-60MT-CM
MITSUBISHI PLC FX3GA-60MT-CM
Input and output points: 60 points. Powe
MITSUBISHI
PLC
FX3GA-40MT-CM
MITSUBISHI PLC FX3GA-40MT-CM
Input and output points: 40 points. Powe